1000 BTU ~ 1 CFH |
|
|
Scenario 1, Full gas load, full electrical load |
Quantity |
BTU
Rating of Each Appliance |
Total
BTU |
Min
Pressure, inches Water Column |
Max
Pressure, inches Water Column |
Notes |
|
|
Water Heater |
1 |
40,000 |
40,000 |
|
10.5 |
|
|
Furnace |
1 |
80,000 |
80,000 |
|
10.5 |
|
|
Oven, burner |
1 |
4,500 |
4,500 |
|
10.5 |
|
|
Oven, burner |
1 |
9,200 |
9,200 |
|
10.5 |
|
|
Oven, burner |
1 |
9,200 |
9,200 |
|
10.5 |
|
|
Oven, burner |
1 |
10,000 |
10,000 |
|
10.5 |
|
|
Oven, oven |
1 |
16,000 |
16,000 |
|
10.5 |
|
|
Oven, broiler |
1 |
12,000 |
12,000 |
|
10.5 |
|
|
Clothes Dryer |
1 |
22,000 |
22,000 |
3.5 |
10.5 |
|
|
Gas Fireplace |
1 |
25,000 |
25,000 |
3.5 |
10.5 |
|
|
Standby Generator |
1 |
240,000 |
240,000 |
11 |
14 |
Generator,
Full load |
|
|
|
Total |
467,900 |
|
|
|
|
|
Scenario 2, Full gas load, 1/2 electrical load |
Quantity |
BTU
Rating of Each Appliance |
Total
BTU |
Min
Pressure, inches Water Column |
Max
Pressure, inches Water Column |
Notes |
|
|
Water Heater |
1 |
40,000 |
40,000 |
|
10.5 |
|
|
Furnace |
1 |
80,000 |
80,000 |
|
10.5 |
|
|
Oven, burner |
1 |
4,500 |
4,500 |
|
10.5 |
|
|
Oven, burner |
1 |
9,200 |
9,200 |
|
10.5 |
|
|
Oven, burner |
1 |
9,200 |
9,200 |
|
10.5 |
|
|
Oven, burner |
1 |
10,000 |
10,000 |
|
10.5 |
|
|
Oven, oven |
1 |
16,000 |
16,000 |
|
10.5 |
|
|
Oven, broiler |
1 |
12,000 |
12,000 |
|
10.5 |
|
|
Clothes Dryer |
1 |
22,000 |
22,000 |
3.5 |
10.5 |
|
|
Gas Fireplace |
1 |
25,000 |
25,000 |
3.5 |
10.5 |
|
|
Standby Generator |
1 |
149,000 |
149,000 |
11 |
14 |
Generator,
1/2 load |
|
|
|
Total |
376,900 |
|
|
|
Scenario 3, Typical gas load, Typical electrical load |
Quantity |
BTU
Rating of Each Appliance |
Total
BTU |
Min
Pressure, inches Water Column |
Max
Pressure, inches Water Column |
Notes |
|
|
Water Heater |
1 |
40,000 |
40,000 |
|
10.5 |
|
|
Furnace |
1 |
80,000 |
80,000 |
|
10.5 |
|
|
Oven, burner |
1 |
5,000 |
5,000 |
|
10.5 |
|
|
Oven, burner |
1 |
9,200 |
9,200 |
|
10.5 |
|
|
Oven, oven |
1 |
16,000 |
16,000 |
|
10.5 |
|
|
Clothes Dryer |
1 |
22,000 |
22,000 |
3.5 |
10.5 |
|
|
Gas Fireplace |
1 |
25,000 |
25,000 |
3.5 |
10.5 |
|
|
Standby Generator |
1 |
120,000 |
120,000 |
11 |
14 |
Generator,
typical load |
|
|
|
Total |
317,200 |
|
|
|
Scenario 4, Typical gas load, Typical electrical load |
Quantity |
BTU
Rating of Each Appliance |
Total
BTU |
Min
Pressure, inches Water Column |
Max
Pressure, inches Water Column |
Notes |
|
|
Water Heater |
1 |
40,000 |
40,000 |
|
10.5 |
|
|
Furnace |
1 |
80,000 |
80,000 |
|
|
|
|
Oven, burner |
1 |
5,000 |
5,000 |
|
10.5 |
|
|
Oven, burner |
1 |
9,200 |
9,200 |
|
10.5 |
|
|
Oven, burner |
1 |
10,000 |
10,000 |
|
10.5 |
|
|
Clothes Dryer |
1 |
22,000 |
22,000 |
3.5 |
10.5 |
|
|
Standby Generator |
1 |
120,000 |
120,000 |
11 |
14 |
Generator,
typical load |
|
|
|
Total |
286,200 |
|
|
|
|
|
|
|
|
|
|
|